Cardiovascular Rehabilitation With a WCD—Data From the CR3… : Journal of Cardiopulmonary Rehabilitation and Prevention
ergoing CR with a WCD. Methods: We performed a retrospective analysis of all patients with a WCD who completed a CR in Austria (2010-2020). Results: Patients (n = 55, 60 ± 11 yr, 16% female) with a median baseline left ventricular ejection fraction (LVEF) of 36 (30, 41)% at the start of CR showed a daily WCD wearing duration of 23.4 (22, 24) hr. There were 2848 (8 [1, 26]/patient) automatic alarms and 340 (3 [1, 7]/patient) manual alarms generated. No shocks were delivered by the WCD during the CR period. One patient had recurrent hemodynamically tolerated ventricular tachycardias that were controlled with antiarrhythmic drugs. No severe WCD-associated adverse events occurred during the CR stay of a median 28 (28, 28) d. The fabric garment and the device setting needed to be adjusted in two patients to diminish inappropriate automatic alarms. Left ventricular ejection fraction after CR increased significantly to 42 (30, 44)% (P < .001). Wearable cardioverter-defibrillator therapy was s